Description:
!!!Warning: This version for NTA NX3-1000E/2000E devices only!!!
[Source Version]
V4.5R90F04,V4.5R90F04SP01,V4.5R90F04SP02,V4.5R90F04SP03
[Target Version]
V4.5R90F04SP04
[Matching Versions of Collaborative Devices]
ADS: V4.5R90F04SP03
ADSM: V4.5R90F04SP02
TAT: V2.0.0
MF: V4.5R90F01SP05
[Function Description]
1. Some bugs are fixed.
Fixed Bugs:
NTA-11119: The description of where to enable IP traffic query needs to be modified in the IP Traffic Query section.
NTA-11115: After the user account web page is refreshed, there is a probability that users are unable to use the Add and Edit buttons.
NTA-10870: When specific operations are performed and regions are selected as objects, region names are not displayed in the email sending configuration.
NTA-10869: When default custom alerts are filtered for the alert query, the query result is blank.
NTA-11342: The exported threat intelligence alert data contains JavaScript code information.
NTA-11386: There are some problems in NTA documents.
NTA-11391: There is a problem with Flowspec diversion triggered by manual bulk withdrawal of two DDoS traffic diversions.
NTA-10691: After the top 300 diversions are triggered in a region, if the diversion parameter is changed to non-diversion, the diversion is not actually canceled.
NTA-11373: When the rule base is used in a group, if users switch the mode, the auto-learned baseline will not be updated.
NTA-11360: The number of alerts for the monitored regions is abnormal (alerts related to the rule base and threat intelligence are not included).
NTA-11345: There is a continuous inadequate display of alerts in the monitored regions.
NTA-11294:The syntax of the curl command with the except parameter has an error.
NTA-11278:When configuring the alert hierarchy, if the medium-level alert ratio is set higher than the high-level alert ratio, the system prompts that the settings are incorrect.
NTA-11277: The displayed location of the DDoS alert plugin in the custom template is incorrect.
NTA-11266: There is an instance error in the API manual.
NTA-11427: Some console port command functions have exceptions. Users cannot log in to the web-based manager after the .init file is fixed.
NTA-11390: sftp-send-data.py has multiple processes running simultaneously, which consumes a significant amount of CPU.
NTA-11274: There is a problem with the print output of readtt read 1111.
NTA-11322 After the alert triggered by low-volume traffic ends immediately and traffic is merged, the peak traffic is displayed as 0.
NTA-11324: Some logs are occasionally not sent when an email is sent.
NTA-11366: The Flowspec diversion trigged by the rule base alert has incorrect settings.
NTA-11367: When the rule base mode is switched, the alert manager engine error occurs.
NTA-11368: When short-term traffic triggers a region alert, the peak traffic displayed in the alert description falls below the threshold.
NTA-11387: The KVM virtual machine displays incorrect time after restart.
NTA-11381: When the system language is English, the email contains Chinese characters.
NTA-11355: NTA fails to send .json files when collaborating with ADBOS in the IPv6 environment.
|